Shower Screen & Trim Leaks
What it is
Water escapes past the shower screen containment barrier during a basic flow test, failing standard water-tightness provisions. The adjoining perimeter wall tiling lacks a protective finishing edge bead or frame and was haphazardly coated in paint.
The shower boundary terminates directly against the door jamb without waterproofing behind the trim, exposing raw plasterboard edges. Thermal testing confirmed water rapidly wicks into the timber door jamb and adjacent bedroom partition.