Substandard substrate preparation and surface defects
What it is
The external terrace concrete substrate was left rough, dusty, and uneven with formwork deformations prior to membrane application. Applying membrane over un-prepared surfaces breaches manufacturer specifications and AS 4654.
The liquid waterproofing membrane on the balcony exhibits noticeable pinholes, excessive uneven thickness, and is peeling off the substrate. The work demonstrates severe workmanship defects.
Substrate preparation on the balcony contains ridges, bumps, and uneven hollows unsuitable for sheet membrane application.
Standards
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Footings slabStairs balustrades decks
Video examples
- I Inspected a Billionaire’s Mansion 1:01:10 majorSubstrate for external membrane poorly prepared with bumps and voids
- I Inspected Troy Candy's Multi-Million Dollar Home: Shocking Finds! 15:06 majorSubstandard balcony membrane application with pinholes and debonding
- I inspected a $20 Million Government Housing Build 23:23 majorUnsuitable substrate preparation for external waterproofing
- I Uncovered a $1.1M NSW Building Catastrophe 17:46 majorPinholes and uncleaned concrete substrate under membrane