Waterstop disconnection from flashing and membrane termination defects
What it is
Water stops installed at doorway thresholds in the main bathroom and ensuite fail to connect to the perimeter waterproofing flashings. Because continuity is broken, the waterproofing systems are non-compliant.
The shower opening water stop angle is not properly tied into or connected with the perimeter flashing. This breaks continuous containment and allows moisture to escape the wet area.
Waterproofing inside wet areas is non-compliant due to incorrect or missing water stop trims. In addition, the laundry and bathrooms lack essential sanitary fittings such as the basin and toilet seat at final inspection.
Standards
- AS 3740 Said in videoSuggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Finishes painting tilingPlumbing
Video examples
- She Bought a $900K Home. It’s Worth $175K Now... 22:05 majorBathroom water stops not connected to perimeter flashings
- Builder LOSES IT During Inspection – Crazy Confrontation! 12:11 majorWater stop angle not connected to perimeter flashing in shower
- $500,000 Build | Is This Australia's Most Overrated Build… 14:12 majorNon-compliant waterproofing membrane termination and missing bathroom fixtures
- I Caught This Waterproofing Contractor On Bodycam… 1:34 majorMissing vertical upstand and membrane return at waterstop
- I Caught This Waterproofing Contractor On Bodycam… 3:04 majorWaterstop installed over dirt and disconnected from perimeter flashing
- I Caught This Waterproofing Contractor On Bodycam… 5:07 majorMembrane not carried up full face of aluminium waterstop in shower
- I Caught This Waterproofing Contractor On Bodycam… 6:48 majorDiscontinuous doorway waterstop and perimeter flashing connection
- I Inspected Australia's Best House… 8 Years Later 18:19 majorSecondary bathroom water stop missing proper return and membrane tie-in
- I inspected a $20 Million Government Housing Build 10:24 majorDiscontinuous perimeter flashing and membrane termination