Movement and control joint defects in Hebel and cladding
What it is
Stacker stone tiles were fixed continuously across internal and external corners and over substrate relief points without movement joints. The absence of movement relief has caused visible cracking and creates a severe delamination hazard.
External aerated concrete cladding lacks required vertical control joints and damp-proof coursing. Unconnected stormwater drains are discharging runoff directly along the perimeter footings.
The external Hebel wall panels lack the required control joints specified in the manufacturer's installation manual. This omission prevents normal building movement and leads to cracking.
Standards
- AS 2870 Suggested reference, unverified
- AS 3958.1 Suggested reference, unverified
- AS 5146.1 Suggested reference, unverified
- Manufacturer instructions Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Drainage stormwaterFinishes painting tilingStairs balustrades decksStructural framingWindows doors
Video examples
- $2.1 Million To Build & $250,000+ To Manage! 15:41 majorMissing movement joints in tiled external Hebel walls
- Rogue Builder Exposed: Illegal Construction Nightmare! 20:17 majorMissing Hebel control joints, missing DPC, and uncontrolled stormwater
- The Ugly Truth of New Homes: Exposing Neglect and Deception 0:59 majorMissing vertical control joint in Hebel external cladding
- The Ugly Truth of New Homes: Exposing Neglect and Deception 1:12 majorRetrofit control joint not cut completely through panel
- The Ugly Truth of New Homes: Exposing Neglect and Deception 4:50 majorOmission of control joint above external door opening
- The Ugly Truth of New Homes: Exposing Neglect and Deception 6:08 majorExcessive control joint spacing on boundary wall on Class P site
- I Inspected Her Brand New Home… It’s Worse Than It Looks 7:05 majorMissing internal and external control joints in Hebel cladding
- I Unraveled a $750K Construction Disaster: NSW Build Exposed! 24:57 majorExcessive continuous cladding span without movement control joints