What it is

The builder installed an undersized single floor drain instead of the specified linear strip drain. Small timber blocks were also left placed over the balcony floor, puncturing and damaging the waterproofing membrane.

The outdoor terrace slot drain grate is supported merely by riveted aluminium angles and side tiles that flex easily underfoot. This improvised support lacks structural rigidity to carry pedestrian traffic.

The drainage sump installed on the external balcony has no supporting structure beneath it. Without structural support, movement and settlement can crack the surrounding membrane and create water ingress points.

Standards