Inspection Library

Drainage stormwater

Other drainage stormwater defects

7 examples in 6 videos 3 major 4 minor

Ungrouped: a mixed bucket of unrelated defects in this element that did not fit another topic. They are not one common problem.

What it is

Roof sections lack gutters specified in the approved plans, resulting in uncontrolled discharge directly onto lower surfaces and wall junctions. Omitting these gutters breaches the contract documents and risks ponding along the building line.

Surrounding landscaped surfaces do not fall away from the overflow relief gully (ORG). Surface water can pool around the gully and enter the drainage system.

A charged stormwater line serving a 30,000 L rainwater tank lacks leaf strainers and adequate low-point drainage facilities. Stagnant water and debris remain trapped in underground pipework without a 1:100 fall or an approved performance solution.

Standards

Explained in our own words. Check the current edition; which edition applies depends on the building permit date.

Also relevant to

PlumbingRoofingSite works landscapingStairs balustrades decksWaterproofing wet areas