Inspection Library

Footings slab

Other footings slab defects

8 examples in 8 videos 7 major 1 minor

Ungrouped: a mixed bucket of unrelated defects in this element that did not fit another topic. They are not one common problem.

What it is

An undersized, non-suspended driveway slab was cast directly over a buried pipe subject to vehicle traffic loading. Concentrated vehicle point loads directly transfer pressure to the conduit, threatening pipe rupture.

Marking spray paint was applied directly across the reinforcing steel prior to pouring. Specifications require reinforcing bars to remain clean and free of paint, grease, and contaminants to ensure proper concrete bond.

External pedestrian concrete pavement was poured over loose bricks, timber offcuts, and uncompacted soil rather than crushed rock. Thickness measures only 70 to 81 mm instead of meeting required minimum depths.

Standards

Explained in our own words. Check the current edition; which edition applies depends on the building permit date.

Also relevant to

Cladding render brickworkDrainage stormwaterPlumbingSite works landscapingStairs balustrades decksStructural framingWaterproofing wet areas