What it is

A floor doorstop fastener was drilled directly through wet area floor tiles and penetrated the underlying waterproof membrane. This breach destroys membrane integrity and allows water to seep directly into ground floor framing below.

Silicone sealant around the built-in shower bench is completely covered in extensive mould infestation. This indicates prolonged moisture retention, improper maintenance, or substandard sanitary sealant application.

A floor penetration and sump were cut directly into the Scyon Secura flooring sheets contrary to manufacturer specifications. This improper installation compromises substrate integrity and voids the manufacturer warranty.