Waterproofing wet areas

Defective or missing waterstop angles and threshold drainage

3 examples in 3 videos 3 major

What it is

Inspection along the master ensuite shower sill reveals that the perimeter waterstop angle profile is improperly installed and non-conforming. This fails National Construction Code waterproofing mandates.

No waterstop termination was installed along the door opening, and the external perimeter lacks a strip drainage system. This allows surface runoff to enter directly into internal living areas.

The external balcony tiling sits higher than the internal floor level instead of providing the required downward step-down or membrane termination height. Additionally, no sub-sill strip drainage was installed to prevent water ingress into the dwelling.