What it is

Ongoing water leaks around the stair and window-to-wall junctions were superficially caulked with heavy silicone instead of proper flashing. The ledge has a backwards fall allowing water accumulation, and unsealed exposed screw heads provide direct water ingress paths.

The shower floor fall measured 32 mm over 600 mm, substantially exceeding the allowable range of 7.5 mm to 10 mm (1:80 to 1:60). This excessive slope creates a severe hazard for disabled wheelchair access.

The bathroom floor slopes backward toward the entry doorway rather than draining to the waste, and lacks a doorway water stop. Escaping bathroom water will flow directly into the adjoining bedroom.