Floor falls and levels (uneven, negative, or excessive falls)
What it is
Ongoing water leaks around the stair and window-to-wall junctions were superficially caulked with heavy silicone instead of proper flashing. The ledge has a backwards fall allowing water accumulation, and unsealed exposed screw heads provide direct water ingress paths.
The shower floor fall measured 32 mm over 600 mm, substantially exceeding the allowable range of 7.5 mm to 10 mm (1:80 to 1:60). This excessive slope creates a severe hazard for disabled wheelchair access.
The bathroom floor slopes backward toward the entry doorway rather than draining to the waste, and lacks a doorway water stop. Escaping bathroom water will flow directly into the adjoining bedroom.
Standards
- AS 1428.1 Said in videoSuggested reference, unverified
- AS 2047 Suggested reference, unverified
- AS 3740 Said in videoSuggested reference, unverified
- AS 4654.2 Suggested reference, unverified
- NCC Said in video
- NCC Vol 2 Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Drainage stormwaterFinishes painting tilingStairs balustrades decksWindows doors
Video examples
- Are Homebuyers Getting Scammed…We Returned to the $2M Disaster 22:07 majorExcessive superficial caulking and inverse fall at leaking junction
- Unveiling Worst Builder of 2024 1:04:02 majorExcessive shower floor fall towards waste
- Unveiling Worst Builder of 2024 1:04:59 majorNegative bathroom floor fall toward doorway into bedroom
- Builder Challenges Inspection Results #siteinspections #tiktokinspector #inspection 2:20 majorUneven and non-compliant fall in shower floor tiling