Missing or Defective Shower Waterstop Angles

18 examples in 13 videos 17 major 1 minor

What it is

Thermal imaging confirmed water escaping a raised shower hob within a minute of testing, indicating that no continuous waterstop was installed to retain water.

The enclosed shower lacks an aluminium waterstop angle extending 5 mm to 15 mm above the finished tile line. Furthermore, the shower screen fixing screws were driven directly into the tiles, puncturing the waterproofing membrane.

Physical testing under the shower screen confirmed the absence of the required vertical water stop angle. Without this barrier, moisture beneath tiles will migrate across the bathroom floor.