Non-compliant or missing balcony overflow drainage devices
What it is
An enclosed upper balcony lacks any overflow provision to external atmosphere at the finished surface or membrane level. In the event of primary drain blockage, water can pool and penetrate interior building elements.
Balcony overflow provisions fail to comply with external waterproofing standards because the membrane does not turn into the drain fitting and the discharge route is undefined.
The secondary overflow drain is situated within the floor deck instead of discharging through a wall weir, meaning blockages of primary outlets can allow water to pond and flood into the home.
Standards
- AS 4654 Said in video
- AS 4654.2 Suggested reference, unverified
- AS/NZS 3500.3 Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Drainage stormwaterPlumbingStairs balustrades decks
Video examples
- Paid in Full, Yet Scammed? Unearthing a $1M NSW Building Nightmare! 5:11 majorEnclosed balcony constructed without overflow device
- I Uncovered a $1.1M NSW Building Catastrophe 12:35 majorNon-compliant balcony overflow drain installation
- I Uncovered a $1.1M NSW Building Catastrophe 14:51 majorBalcony overflow outlet incorrectly located in floor plane